Double-effect energy conservation evaporation concentrator
First, use: this concentrator adapts in fluid material and so on traditional Chinese medicine, western medicine, starch rice polishings, food dairy product concentrations, especially is suitable for the heat-sensitivity material low temperature vacuum concentration.
Second, characteristic and benefit: The energy conservation benefit, according to the SJN-1000 computation, the year saves about the vapor 3500 tons, saves about the water 90,000 tons, saves about electricity 80,000 kwh, folds the Renminbi 10 - 150,000 Yuan (and single effect contrast) 2. This concentrator uses outside the negative pressure to heat up the nature circulation-like evaporation way, the evaporation velocity is quick, the concentration proportion is big, may reach 1.2-1.35 (common traditional Chinese medicine to extract).
3. this concentrator uses two effect also to evaporate, two steam obtain the use, the consuming energy total quantity and the single effect concentrator compare reduce 50%, one year energy conservation expense may take back this concentration the complete investment.
4. multi-purpose operating features: (1) may the recovered alcohol density about 80%; (2) single effect, two, three times may repeatedly and the pot receive the paste; (3) may the intermittence, the continuous feed.
5. this concentrator and the material contact spot uses the stainless steel manufacture, meets the GMP requirement. The contour is artistic. Outside the heater, the evaporator high has the heat insulating layer, the heat insulating layer external use stainless steel thin steel plate manufacture outer covering, the surface makes the mirror surface or Asian light processing.
Major technique parameter
Specification model |
SN-500 |
SN-1000 |
SN-1500 |
SN-2000 |
SN-5000 |
SN-8000 |
Greatest transpiration rate kg/h |
500 |
1000 |
1500 |
2000 |
5000 |
8000 |
Steam pressure (Mpa) |
0.03-0.09 |
0.03-0.09 |
0.03-0.09 |
0.03-0.09 |
0.03-0.09 |
0.03-0.09 |
Steam consumption kg/h |
250 |
500 |
750 |
1000 |
1500 |
1600 |
Outside list heater heating area m2 |
6 |
12 |
16 |
20 |
50 |
80 |
Two effect two condensation area m2 |
12 |
20 |
30 |
40 |
98 |
140 |
Steam orifice mm |
DN-50 |
DN-70 |
DN-80 |
DN-80 |
DN-80 |
DN-80 |
Cooling water orifice m/m |
DN-40 |
DN-50 |
DN-60 |
DN-60 |
DN-60 |
DN-76 |
Vaporization temperature ℃ |
An effect |
80 |
Two effect |
70 |
Vacuum degree MPa |
An effect |
0.06 |
Two effect |
0.08 |
External dimensions mm |
Long |
4 |
5 |
6.5 |
5.5 |
6.8 |
7.6 |
Width |
1.5 |
1.7 |
1.8 |
2 |
2 |
2.2 |
High |
3.3 |
3.5 |
4 |
4.2 |
4.5 |
4.8 |
Installation weight Kg |
1450 |
1860 |
2550 |
3350 |
4800 |
6500 |
|